{"product_id":"megger-mft1711-multifunction-tester","title":"Megger MFT1711 Multifunction Tester with Free Calibration Certificate","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 18px;\"\u003eMegger MFT1711 Multifunction Tester\u003cbr\u003eSupplied with a free traceable Calibration Certificate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cp\u003eThe Megger 1711 multifunction tester is suitable for use on domestic, commercial and industrial fixed wire low voltage installations in accordance with the requirements of BS7671.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003ch4\u003e\u003cspan style=\"font-size: 18px;\"\u003eWhat's New for the 1711?\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cp\u003eAs the new version of the 1710, the 1711 comes with a selection of brand new features for an entry-level electrical installation testing tool.\u003c\/p\u003e \u003cp\u003eThese include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eExpanded Insulation Resistance Test Voltage Range to 1kV (1000V) - in the past, the 1000V test voltage was only found on higher-end models in the series\u003c\/li\u003e \u003cli\u003eMax Zs Display - testing final ring circuits? It's quick and easy thanks to the new, large-size Max Zs display on the Megger 1711. There's no need to write down Zs values as you check every socket on a ring; the 1711 will automatically identify and store the highest value you measure\u003c\/li\u003e \u003cli\u003eTrue RMS Voltage Measurements - rest assured that your AC voltage measurements are as accurate as possible, even on irregular waveforms, thanks to true RMS included as standard\u003c\/li\u003e \u003cli\u003eAutomatic RCD Testing - take the hassle out of testing RCDs as the Megger 1711 will do it all for you complete with 10mA RCD and programmable (VAR) RCD compatibility. There's no need to press the test button - tests will start automatically when you apply probes to the circuit (this also works for continuity\/loop testing)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003ch4\u003e\u003cspan style=\"font-size: 18px;\"\u003eWide Range of Electrical Installation Testing Procedures\u003c\/span\u003e\u003c\/h4\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003ch4\u003eWhen you're using the Megger 1711 multifunction tester, you'll see just how much easier your electrical testing can truly become.\u003c\/h4\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cp\u003eThe 1711 gives you quick, easy access to all of your testing procedures via colour-coded rotary dials and dual testing buttons on either side of the MFT make it easy to activate a test, regardless of where you're working.\u003c\/p\u003e \u003cp\u003eYou can expect all of the following measurement procedures when using the MFT1711:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eContinuity\/Resistance - complete with 200mA range and automatic continuity test start\u003c\/li\u003e \u003cli\u003eInsulation Resistance - including test voltage display, full protection against live circuits and selectable test voltages of 1kV (1000V), 500V and 250V\u003c\/li\u003e \u003cli\u003eEarth Loop Impedance - 2-wire no trip test (L-PE), 3 wire no trip test (L-PE), 2 wire high current testing and the ability to display PSCC or PFC calculations alongside loop resistance for easier measurements. Also includes the Zmax value function\u003c\/li\u003e \u003cli\u003eRCD - compatible with 10, 300, 300 and 500mA RCDs, as well as type A, AC, S and programmable RCDs. Can perform 1\/2, I, I and 5 I tests plus includes automatic RCD tests, ramp tests, 0 and 180° phase angle and touch voltage display from 0 to 230V\u003c\/li\u003e \u003cli\u003eVoltage Measurements - measure AC\/DC voltage from 10V to 600V with true RMS accuracy on AC\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003ch4\u003e \u003cspan style=\"font-size: 18px;\"\u003eK\u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003eeeping You Safe When Testing\u003c\/span\u003e \u003c\/h4\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cp\u003eAccidents happen, so the Megger 1711 is made tough and the to the highest standards of safety. As an entry-level tool, having protection in place means the MFT1711 is ideal for new electrical installers who are still training or newly qualified, ensuring that you don't accidentally connect things up wrong or cause potential danger to yourself or others.\u003c\/p\u003e \u003cp\u003eThe MFT1711's safety features include:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eTest Lock Out - the MFT1711 will block the test from going ahead if there's live voltage on a circuit when you're trying to measure insulation resistance\u003c\/li\u003e \u003cli\u003eSafe Contact Detection - audible and visual warnings let you know when you've done something wrong\u003c\/li\u003e \u003cli\u003eAutomatic Discharge - the 1711 will discharge itself after testing, ensuring your safety at all times\u003c\/li\u003e \u003cli\u003eDust and Weatherproof Casing Rated to IP54 - use the MFT1711 confidently in all conditions\u003c\/li\u003e \u003cli\u003eCAT IV 300V Safety Rating - work on any part of an installation without having to carry out risk assessments about the level of supply transients present\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003ch4\u003e \u003cspan style=\"font-size: 18px;\"\u003eWhat's Included?\u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003c\/span\u003e \u003c\/h4\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMegger MFT1711-BS Multifunction Tester\u003c\/li\u003e \u003cli\u003eHard Carrying Case\u003c\/li\u003e \u003cli\u003ePrinted Quick Start Guide\u003c\/li\u003e \u003cli\u003eFull User Guide on CD\u003c\/li\u003e \u003cli\u003eCalibration Certificate\u003c\/li\u003e \u003cli\u003eMegger Neck Strap\u003c\/li\u003e \u003cli\u003e3 Wire Lead Set with Probes + Clips\u003c\/li\u003e \u003cli\u003eMains Plug Test Lead (BS1363)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size: 18px;\"\u003e\u003cstrong\u003eMegger MFT1711, MFT1721 and MFT1731 Technical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cp\u003ePlease be aware that not all features are available for every model. If a feature is not included on a model, there will be a note next to each section.\u003c\/p\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003cdiv\u003e \u003ctable class=\"ecwid-description-table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eInsulation Tests\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOutput Voltage\u003c\/td\u003e \u003ctd\u003e-0 to +20% at rated load or less\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage Display\u003c\/td\u003e \u003ctd\u003e±3% ±3 digits ±0.5% of rated voltage\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eShort Circuit Current\u003c\/td\u003e \u003ctd\u003e1.5mA nominal test current\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTest Current on Load\u003c\/td\u003e \u003ctd\u003e1mA at min pass values of insulation\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation Accuracy\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e1000V\u003c\/td\u003e \u003ctd\u003e10kΩ to 999MΩ (±3% ± 2 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003e500V\u003c\/td\u003e \u003ctd\u003e10kΩ to 500MΩ (±3% ± 2 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u0026gt;500MΩ (±10% ± 4 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003e250V\u003c\/td\u003e \u003ctd\u003e10kΩ to 250Ω (±3% ± 2 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u0026gt;250MΩ (±10% ± 4 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003e100V\u003c\/td\u003e \u003ctd\u003e10kΩ to 100MΩ (±3% ± 2 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u0026gt;100MΩ (±10% ± 4 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResistance and Continuity\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003eRange and Accuracy\u003c\/td\u003e \u003ctd\u003e0.01 to 99.9Ω (±2% ± 2 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e100 to 99.9kΩ (±5% ± 2 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOpen Circuit Voltage\u003c\/td\u003e \u003ctd\u003e5V ± 1V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003eTest Current (0 to 2Ω)\u003c\/td\u003e \u003ctd\u003e205mA ±5mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e15mA ±5mA (user selectable)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLoop Test\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLive to Earth\/Neutral Supply\u003c\/td\u003e \u003ctd\u003e48 to 280V (45 to 65Hz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLive to Live Supply (Not Available on MFT1711)\u003c\/td\u003e \u003ctd\u003e48 to 500V (45 to 65Hz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eL-N\/L-L Tests\u003c\/td\u003e \u003ctd\u003e±5% ±5 digits\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003eL-E Tests\u003c\/td\u003e \u003ctd\u003e0.1 to 39.9Ω (±5% ±5 digits ± noise margin)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e40Ω to 1000Ω (±10% ± 5 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay Range\u003c\/td\u003e \u003ctd\u003e0.01 to 1000Ω\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLive to Earth PFC Range\u003c\/td\u003e \u003ctd\u003e20kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLive to Live PSCC Range\u003c\/td\u003e \u003ctd\u003e20kA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRCD Tests\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSupply up to 100mA\u003c\/td\u003e \u003ctd\u003e48 to 480V (45 to 65Hz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSupply up to 1A\u003c\/td\u003e \u003ctd\u003e48V to 280V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRCD Type\u003c\/td\u003e \u003ctd\u003eType AC, A and S\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNo-Trip Test (1\/2xI)\u003c\/td\u003e \u003ctd\u003e-10 to -0%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Test (1xI, 2xI and 5xI)\u003c\/td\u003e \u003ctd\u003e+0 to +10%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRamp Test Touch Voltage (0 to 253V)\u003c\/td\u003e \u003ctd\u003e±5% +15% ±0.5V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Time\u003c\/td\u003e \u003ctd\u003e±1% ±1ms\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTrip Current\u003c\/td\u003e \u003ctd\u003e±5%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cem\u003eStep Increments\u003c\/em\u003e\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVAR (Variable RCD Selection)\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e10mA to 50mA\u003c\/td\u003e \u003ctd\u003e1mA steps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e50mA to 500mA\u003c\/td\u003e \u003ctd\u003e5mA steps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e500mA to 1000mA\u003c\/td\u003e \u003ctd\u003e10mA steps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSupply Measurement\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage\u003c\/td\u003e \u003ctd\u003e10V to 600V (15 to 400Hz) True RMS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eVoltage Accuracy\u003c\/td\u003e \u003ctd\u003e±3% ±1V ±2 digits\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePhase Rotation Indication\u003c\/td\u003e \u003ctd\u003eL1-L2-L3 and L1-L3-L2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrequency\u003c\/td\u003e \u003ctd\u003e15Hz to 99Hz (±0.5% ±1 digit)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eFrequency Resolution\u003c\/td\u003e \u003ctd\u003e0.1Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMFT1711 and MFT1721\u003c\/td\u003e \u003ctd\u003eIEC LR6 type AA alkaline batteries\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMFT1731\u003c\/td\u003e \u003ctd\u003e1.2V NiMH Rechargeable Batteries\u003cbr\u003eMains charger for on-board recharging (4 hours typical)\u003cbr\u003e12V optional car charger available\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEarth\/Ground Test (MFT1731 Only)\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResolution\u003c\/td\u003e \u003ctd\u003e0.01Ω\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent\u003c\/td\u003e \u003ctd\u003e0.45mA or 4.5mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eNoise Rejection\u003c\/td\u003e \u003ctd\u003e20V pk\/pk (7V rms)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003eMax Probe Resistance (Rp and RC)\u003c\/td\u003e \u003ctd\u003e100kΩ @ 50V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e5kΩ at 25V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"2\"\u003e2 and 3 Pole Method\u003c\/td\u003e \u003ctd\u003e0.01 to 1.999kΩ (±2.0% ± 3 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eART method (1.00Ω to 1.999kΩ) with accuracy of ±5.0% ± 3 digits\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStakeless Method\u003c\/td\u003e \u003ctd\u003e1.00 to 199Ω (±7.0% ± 3 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCurrent (Via Optional Clamp Meter)\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRange\u003c\/td\u003e \u003ctd\u003e0.1mA to 200A AC (5.0% ± 3 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResolution\u003c\/td\u003e \u003ctd\u003e0.1mA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMV Sensor Input (MFT1721 and MFT1731)\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIncluding Temperature\u003c\/td\u003e \u003ctd\u003e0.0mV to ±199.9mV DC (±1.0% ± 2 digits)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResolution\u003c\/td\u003e \u003ctd\u003e0.1mV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eData Storage (MFT1731 Only)\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCapacity\u003c\/td\u003e \u003ctd\u003e1000 results\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003ctd\u003eBluetooth\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSafety\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd rowspan=\"5\"\u003eIEC 61010-1: 2010\u003cbr\u003eIEC 61010-30: 2010\u003cbr\u003eIEC 61010-031: 2008\u003cbr\u003e600V CAT III \/ CAT IV 300V (Max phase to phase 600V)\u003cbr\u003eIEC 61557: 2007 parts 1 to 10\u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eEMC\u003c\/td\u003e \u003ctd\u003eIEC61326 edition 2 location class B\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating Temperature Range and Humidity\u003c\/td\u003e \u003ctd\u003e-10 to +55°C (90% RH at +40°C max)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorage Temperature Range and Humidity\u003c\/td\u003e \u003ctd\u003e-25 to +70°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMaximum Altitude\u003c\/td\u003e \u003ctd\u003e2000m\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight (Instrument and Case)\u003c\/td\u003e \u003ctd\u003e1kg (with batteries)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions (Instrument and Case) - MFT1711 and MFT1721\u003c\/td\u003e \u003ctd\u003e150mm x 85 x 235mm (H x W x D)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions (Instrument and Case) - MFT1731\u003c\/td\u003e \u003ctd\u003e220 x 390 x 285mm (H x W x D)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eIP Rating\u003c\/td\u003e \u003ctd\u003eIP54\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCalibration Temperature\u003c\/td\u003e \u003ctd\u003e+20°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTemperature Coefficient\u003c\/td\u003e \u003ctd\u003e\u0026lt;0.1% per °C\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e","brand":"Megger","offers":[{"title":"No Calibration Certificate Required","offer_id":41287057047616,"sku":"1008-121","price":707.78,"currency_code":"USD","in_stock":true},{"title":"Calibration Certificate Required (+£0.00)","offer_id":41287057080384,"sku":"1008-121-CAL","price":707.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/6342\/4320\/files\/MeggerMFT1711MultifunctionTester.jpg?v=1782612150","url":"https:\/\/wearvico.com\/products\/megger-mft1711-multifunction-tester","provider":"wearvico","version":"1.0","type":"link"}